We are running Reflection 5.2 under Windows 95. We have a series of
programs that are supposed to write display data to IMAGE. They were
compiled and linked in batch jobs. They fail with condition word -11,
bad database reference. The code looks fine. I recompiled and relinked
the program and its subroutines. They still fail. In desperation, I sign
off, close and restart Reflection, and sign back on. The program now
works. I try this several more times with the same results. I start to
remember fairy tales about gremlins... I wonder if I should read Sagan's
"The Demon-Inhabited World".