Hi folks
Our client is running a Series e3000/A400-100-15 running C.75.00.
Until now they have done the backup on DDS. Lately they had failure on the DDS drive and we have realized that it is getting difficult to get new tapes.
They have now decided to move to DLT8000 and have bought two of them - C6378A. One is supposed to go live on the system and the other to be stored as a spare device.
Also they have got two c2363b cables. They are rather long, but they should work.
As far as I can see in the "Communicator e3000 MPE/iX Release 7.5 (Software Release C75.00)" this should be ok.
I have connected one of the DLT's to the "Ultra Wide SCSI" interface with path 0/0/1/0.
When I run the ODE/Mapper2 the DLT is not recognized.
I have tried to change between the two DLT's and the two cables. It does not change anything.
I have tried to cheat it by adding the device in ioconfig by adding first the path 0/0/1/0.2 and then the device with this command: ad 8;path=0/0/1/0.2.0;ID=dlt;mode=autoreply
In that case I get the following error:
Configuration of the device in low-level I/O failed (IOCONFIG 1)
Any ideas?
Venlige hilsner/Best regards
Torben Olsen
Konsulent
Datacon A/S
Direkte: 48 133 026
Mobil: 28 355 886
Email/SIP: [log in to unmask] <mailto:[log in to unmask]>
Hejrevang 13 - 3450 Allerød
Telefon: 48 133 133 - www.datacon.dk<http://www.datacon.dk/>
[image001]<http://datacon.dk/om-datacon/publikationer/dc-magazine>
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *