Ray Shahan writes
Hi all,
I'm doing a DBFIND using an Omnidex key built with:
CREATE CATALOG-ITEM MULTIPLE FROM XREF-SOURCE[1:4] & EDA-ITEM
If my key is (and the quotes are part of the key's value "SSF1567785",
everything looks good, but if my key value has a space "JLH 1567785", then
the DBFIND fails. I'm assuming there's a parm on the key build that's
missing (or incorrect), but my Omnidex skills are minimal...
Any clues/help?
------------------------------------------------
The Omnidex Imageplus API guide says on page 2-108 that there are two ways
to terminate the argument parameter of a full key value:
1. with a semicolon
2. with trailing blanks up to the length of the key
Try adding a semicolon at the end of the field. It may see the blank as the
end of the key.