Hi everybody,
storms and subsequent power failure last night!
the message on the console(when we came in this morning):
System abort 1740 from subsytem 107
Secondary Status info = -35; subsys = 113
System Halt 7, $06CC
Blinking: FLT DEAD, FLT BF07, FLT 0106, FLT 02CC
Well, we rebooted (with Start) with the same result.
We rebooted with Norecovery and the messages were a little different:
System abort 2052 from subsytem 145
System Halt 7, $0804
Blinking: FLT DEAD, FLT BF07, FLT 0108, FLT 0204
It seems, the booting process is going well, but just as the startup and
setcatalog are initiated the abort happens.