Hello all.
My posting was based on the error provided. The problem reported was
against 5.5 but has not been seen really since 6.5.
Since this is a 7.5 system and the tape drive reported problems, the error may
have been as a result of a dirty drive.
There are a few ways to debug the issue. Dave if you should seen this
problem again, would you send me the details with the following;
Add the following line before the sysgen command
setdump;debug="tr,i,d;abort"
If sysgen aborts again with the same or similar error this will provide a starting
point of why the abort occured.
The current version of store is: MPEMX93(C) for 7.5 changes the version of
STORE/TurboSTORE to C.75.02. This was on the pp05 update so you
probably have this version of store.
Best Regards
Cathlene Mc Rae
HP SR. Response Center Engineer
[log in to unmask]
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *