Craig asks:
> Everyone... (and Bill),
>
> A couple years ago I posted a strange showq on MPE/iX 7.5 (N-class 750/400)
>
> :showq ;status
>
> ------QUANTUM-------
> QUEUE BASE LIMIT MIN MAX ACTUAL BOOST TIMESLICE
> ----- ---- ----- --- --- ------ ----- ---------
> CQ 152 200 20 200 20 DECAY 200
> DQ 202 238 -1726 -1726 -1726 DECAY 400
> EQ 240 253 2000 2000 2000 DECAY 200
>
> :
>
> This issue has been resolved on some sites, but I don't know how? Is there a patch?
>
> Regards,
>
> -Craig
Hi Craig,
Yes, the patch was MPEMXK3 which has been superseded for each release in the 2 years since we corrected that. The patches are:
6.5 - MPEMXR6
7.0 - MPEMXQ3
7.5 - MPEMXT0
And I forgot to write down the A,B or C suffix before I logged off the HP net so I
could send this :-( I think you can get the full patch ID from ITRC when you order it.
The problem, if anyone cares was that the quantum values were being stored as
integers and for N-classes, specifically the 750Mhz the value could exceed the max an integer could hold resulting in a negative value when displayed via showq;status.
hth,
Bill
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|
|
|