Dear Jim and other Netters,

Dynamic configuration of DTC is a new feature in MPE 5.5, in most of the
older versions of MPE it is/was not possible.

Greetings,


Jan Gerrit Kootstra.


May MPE survive the year 2k, for it still runs ok.


Jim Phillips heeft geschreven in bericht
<[log in to unmask]>...
Well, I feel really strange and I may show my ignorance here, but I have to

correct Wirt's response in just a teeny, tiny little bit:

Wirt says:

>Yes. Changes you make in NMMGR aren't transferred to the DTC without doing
a
>shutdown and a start norecovery. As to its importance, it actually matters
a

Maybe prior to MPE/iX 5.5.  I'm on 5.5 and I have made numerous changes to
DTC configs in NMMGR, including defining an entirely new DTC.  In every
case
I was able to activate the new config by doing a RESET on the DTC in
TERMDSM within SYSDIAG.  The reset performs a code download to the DTC (it
also aborts all the other users on that DTC's ports) and thereby activates
the new config.

Jim Phillips                            Manager of Information Systems
Voice: (330) 527-2124                   Therm-O-Link, Inc.
  Fax: (330) 527-2123                   PO Box 285; 10513 Freedom St.
Email: [log in to unmask]       Garrettsville, Ohio  44231