text/plain (36 lines)
     What I am doing to capture this data is to turn on the two FCLOSES in
     the IO subsystem of SYSGEN.  After a shutdown and restart this logs
     FCLOSEs to the LOGFILES and can be viewed by SYSDIAG (logtool).

     If you want to only count the FCLOSES then you can use FILERPT program
     written by I believe Allegro Consultants.

     This is a very brief summary and something I am NOT very familiar with
     (so someone please correct me if I am wrong).  If you want more
     details feel free to email me back.

     Hope it helps,

    ---------------------------------------------------------------
    Barry Durand            "The opinions expressed in this
    Systems Engineer II      email are not necessarily the
    Gulf South Health Plans      opinions of my employer"
    [log in to unmask]
    ---------------------------------------------------------------



______________________________ Reply Separator _________________________________
Subject: Image I/O monitor?
Author:  <[log in to unmask]> at SMTP-PO
Date:    5/20/98 2:17 PM


OKO - What's a good tool to monitor read/write activity to Image
datasets? (total reads/writes per dataset over time).

Joe Alexander                  (301) 898-7025 ext 2296
Systems Manager            fax (301) 845-2867
Biowhittaker, Inc.             [log in to unmask]
Walkersville MD