Cynthia Fowler <[log in to unmask]>
Reply To:
Cynthia Fowler <[log in to unmask]>
Date:
Fri, 2 Oct 1998 12:08:19 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (40 lines)
FWIW, we installed this patch first on our development box to workout any kinks. The only "gotcha" we encountered was due to the HPPATH variable redirect for our 3rd party software (NBSpool, JMS/3000, etc.). Prior to running Patch/iX, we had to type:

     :SETVAR HPPATH "!HPGROUP,PUB,PUB.SYS"

including the " " marks (I was told by HPRC that this is the default). Patch/iX blows up without this statement if the variable is redirected for similar 3rd party software. Installing on our test/ development box took 6-8 hours including several calls to HPRC.

Installation on our three production boxes took 2 hours for Phase 1 (NON- exclusive access) and 1.5 hours for Phase 2 (exclusive access) and went smoothly. We did Phase 2 simultaneously on all the boxes. Not a single hitch. Total downtime to the users: 1.5 hrs.

Cindee Bridges-Fowler                           [log in to unmask]
IMC Global, Inc.
Overland Park, KS

>>> Gilles Schipper <[log in to unmask]> 09/28 5:52 pm >>>
I vote "yes".

I've installed it at more than a dozen customers without a single
significant problem.


At 06:27 PM 98/09/28 -0400, Joe Geiser wrote:
>I have here, on my desk, my MPE/iX PowerPatch 5 Tape, ready for install.
>
>I've seen some horror stories here, and heard them elsewhere.  I've also
>heard good things.
>
>So the question is - for anyone who wants to answer - should I, or shouldn't
>I, update the 918DX to PP5?
>
>TIA,
>Joe ("I hate to be the first on the block, but...") G.
>
>
---------------------------------------------------------------------------
Gilles Schipper
GSA Inc.
HP3000 & HP9000 System Administration Specialists
300 John Street, Box 87651   Thornhill, ON Canada L3T 7R4
Voice: 905.889.3000     Fax: 905.889.3001
Internet:  [log in to unmask]
---------------------------------------------------------------------------