On 4/2/14 1:52 PM, Craig Lalley wrote:
> I wonder if there is an OS patch that resolves this? I assume Barry's system
>is fully patched. Is Tracy's?
Quite the opposite, actually. :)
The system on which I've been testing is running 7.5 PP3; whereas I
believe I've gathered that Tracy's is running 7.5 PP5.
Seems odd, though, that something like this would get broken.
It might be interesting to look at the message catalog on an old 6.0
system to see if CIERR 9030 existed back then. But I don't think I have
adequate motivation to boot ours up.
B.
>> On Apr 2, 2014, at 11:33 AM, Barry Lake<[log in to unmask]> wrote:
>>
>>> On 4/2/14 11:10 AM, Johnson, Tracy wrote:
>>> Maybe you have a SYSTEM logon UDC that sets HPAUTOCONT ON?
>>
>> That shouldn't matter. Whether or not CONTINUE or HPAUTOCONT are enabled, one should
>>still see this error (if the error occurs):
>>
>> Number of pause seconds is out of range. (CIERR 9030)
>>
>> But I haven't seen it in any test yet.
>>
>> And, to satisfy your curiosity:
>>
>>
>> Sauron: stream
>> >!job showvar,manager.sys
>> >!showvar hp@
>> >!eoj
>> #J27
>> >:
>> Sauron: stj 27
>>
>>
>> :JOB SHOWVAR,MANAGER.SYS,PUB.
>> Priority = DS; Inpri = 8; Time = UNLIMITED seconds.
>> Job number = #j27.
>> WED, APR 2, 2014, 11:26 AM.
>> HP3000 Release: C.75.00 User Version: C.75.03
>> MPE/iX HP31900 C.45.05 Copyright Hewlett-Packard 1987.
>> All rights reserved.
>> STREAMED BY BARRY,MANAGER.SYS (#S3) ON LDEV# 4
>> STREAM DATE: WED, APR 2, 2014, 11:26 AM
>>
>> :showvar hp@
>> HPACCOUNT = SYS
>> HPACCTCAP = -4259381
>> HPACCTCAPF = SM,AM,AL,GL,DI,OP,CV,UV,LG,PS,NA,NM,CS,ND,SF,BA,IA,PM,MR,DS,PH
>> HPAUTOCONT = FALSE
>> HPCIDEPTH = 1
>> HPCIERR = 0
>> HPCIERRCOL = 0
>> HPCIERRMSG =
>> HPCMDNUM = 2
>> HPCMDTRACE = FALSE
>> (24/114) Continue? n
>> Sauron:
>>
>>
>> So, it's certainly a mystery. But not one worth spending too much more time on, I'd think.
>>
>> Barry