Subject: | |
From: | |
Reply To: | |
Date: | Mon, 22 Feb 1999 11:38:58 -0600 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Douglas Boyd wrote:
> Greetings Knowledgeable Listers,
^^^^^^^^^^^^^
We'll see... :)
> I'm getting a CS ERROR 0,11 when I perform an RJE command on one of my HP918
> MPE 5.5 pp4. HP Response solution is to shutdown and restart system. Kind of
> frustrating as this happened last month also. I know you there is a reset
> function
> in SYSDIAG>PSIDAD but it does not work. If I remember correctly, I used
> TERMDSM (hum..or was it ABORTIO) to reset the INP card on my old classic.
> Just wondered if anyone has had this problem or has a better solution!
Since the PSI card is configured in NMMGR, you should be able to find
the link name (either in NMMGR or in your network startup -- look in
your SYSSTART file for starters) and then do:
NETCONTROL STOP;NET=PSILAN <-- Assumes the link name is PSILAN
NETCONTROL START;NET=PSILAN Use whatever yours is named!!
Hope this helps,
Patrick
--
Patrick Santucci
Technical Services Analyst
KVI, a division of Seabury & Smith, Inc.
Visit our site! http://www.kvi-ins.com
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
"Why is it that when I was young life was complex because
I lacked experience and now that I'm experienced life is
complex because I'm not young?" - James Trudeau
|
|
|