Subject: | |
From: | |
Reply To: | Kiefer, Steve |
Date: | Fri, 19 Mar 1999 14:43:59 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
I believe this is the error message you get when a database is enabled for
TPI, but the accessing program (or associated TPI XL) can't open the TPI
root file - probably HEALTH0A in this case. An example follows...
:MPEX
%PURGE ACCTNG0A
-----Will purge ACCTNG0A.STEVENK.WORK (code "PRIV", type FB, EOF 64, 80
sectors)
80 sectors will be saved
OK to purge 1 file (y/N)? Y
-----Purging ACCTNG0A.STEVENK.WORK (80 sectors)
80 sectors saved
%EXIT
:QUERY
HP32216D.03.13 QUERY/3000 FRI, MAR 19, 1999, 2:32 PM
COPYRIGHT HEWLETT-PACKARD CO. 1976
>B=ACCTNG
PASSWORD = >>
MODE = >>5
TurboIMAGE Error Message:
UNRECOGNIZED RETURN STATUS: 3950
steve
-----Original Message-----
From: Ron Wallace [mailto:[log in to unmask]]
Sent: Friday, March 19, 1999 1:01 PM
To: [log in to unmask]
Subject: Partial IMAGE data base restore
Please
We have just got in a new faster box, that is still under test. I am doing
some testing on a process and wanted to use the extra resources.
I restored only the parts of an AMISYS data base that I needed to run my
process, the detail sets and the associated masters for the keys I was
using. However when I open the data base using SUPRTOOL or QUERY I get the
Following Error.
query
HP32216D.03.13 QUERY/3000 FRI, MAR 19, 1999, 10:54 AM
COPYRIGHT HEWLETT-PACKARD CO. 1976
>ba=health.data
PASSWORD = >>
MODE = >>5
TurboIMAGE Error Message:
UNRECOGNIZED RETURN STATUS: 3950
>
Thanks
Ron Wallace
|
|
|