Leonard,
You didn't say if the modifications you made to the dataset were
'structural' or 'content'. If 'structural' then you need to have exclusive
access. If 'content' then you can use locking to keep the users away from
the data you need to change.
You should NEVER try to replace a dataset while a database is opened. You
are putting the health of your database at serious risk.
regards,
Robert W.Mills
Systems Development Manager
Windsong Services
(01689) 870622 x3005
Leonard S. Berkowitz wrote:
> We tried to execute PURGELINK on a TurboImage dataset (need to flip a
> modified dataset in its place while the dataset is accessed by other
> processes. PURGELINK is a command we routinely use to install our new
> PowerHouse dictionary (not a file under a posix directory) during
> primetime when we are not able to purge it in the normal way. The
> command returned CIERROR 9011. This was in test mode.
>
> CIERROR 9011 is:
>
> MESSAGE ! SUBSYSTEM INTERNAL ERROR: ! PLEASE CONTACT H.P.
> (CIERR 9011)
>
> CAUSE Internal error occurred due to a RESTDUMP or SETDUMP
> command.
>
> ACTION Contact your system manager or support representative.
>
> Not much help here. We were trying to determine whether we could
> actually execute PURGELINK on a PRIV file. We were executing this
> command within MPEX that does facilitate file operations on PRIV
> files. RESTDUMP and SETDUMP seem irrelevant here.
>
> Any ideas or suggestions?
>
> Thanks.