Hi, Scott

Yes we did, Our HP 979KS shipped with 10BT, we ordered 100BT,
but some of reason 100BT does not shipped with new box,
One of problem we faced it, VT terminal has split millisecond pause
between painting screen,
I thought too much traffic on routing table on our 3-com 100BT  switch

So, we installed 2nd 10BT card with second c-class address to HP to
diversify traffic control, first C-class address connect with DTC and
switch,
second C-class address directly connect to switch.

Now It works fairly well, load balance is good and no hesitance on
screen painting on VT terminal.

Peter C.


Scott Becker wrote in message <[log in to unmask]>...
>Has anyone installed 2 network cards on an HP3000 ?
>If so, can I disable ftp, vtmgr etc on the 2nd card to secure it.  As
>you can guess, this will be the card exposed to the world.
>
>thanks in Advance.
>
>Scott Becker
>
>Pathway Pacific
>Sydney, Australia
>