Hi
You can try write: SETVAR COBRUNTIME '                W'
--------------------
Jacek Piskorz
[log in to unmask]


Charly Tango napisał(a) w wiadomości: <[log in to unmask]>...
>Hello listers,
>
>Last weekend we upgraded our HP3000 from MPE iX 4.0 to 5.5.
>We have lots of powerhouse and cobol applications running.
>
>One of our cobol programs gave the following error:
>
>Filename: F705D01
>File status is 48
>FILE NOT OPENED or MODE INCORRECT [47,48,49,9x] WRITE (COBERR 638)
>Program file: co705011.obj705.pers
>END OF FILE (FSERR 0)
>
>The file mentioned above is a direct file opened I-O, read once and written
>once.
>
>After altering the sequence to:
>    Open Input/read/close and Open Output/write/close
>the problem was solved.
>
>Is this a known bug??
>Are there more bugs like this??
>
>T.I.A.
>Cees Tuinder, Boskalis-Westminster Dredging Co., the Netherlands.
>
>