You should also set the link duplexing to full instead of half if you hub
supports it.
Carl McNamee
Systems Administrator
Billing Concepts
(210) 949-7282
-----Original Message-----
From: Joseph Dolliver [mailto:[log in to unmask]]
Sent: Wednesday, July 19, 2000 7:26 AM
To: [log in to unmask]
Subject: Re: [HP3000-L] LinkControl Stats (bit long)
I have also seen this problem before. You need to remove autosensing and set
the speed to 100mb "only".
----- Original Message -----
From: Paveza, Gary <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, July 19, 2000 7:20 AM
Subject: Re: LinkControl Stats (bit long)
> Looks like it is set to 10 MB. But it also looks like you have
autosensing
> enabled. If you can nail the card to 100 MB (and the switch/hub/whatever)
> also to 100 you're much better off. I've always had trouble getting a 100
> MB card get 100 MB if it has autoswitching enabled.
>
> -------------------------------------------------------------
> Gary L. Paveza, Jr.
> Technical Services Manager
> (302) 761-3173 - voice
> (800) 217-5808 - pager
>
> -----Original Message-----
> From: Kevin O'Sullivan [SMTP:[log in to unmask]]
> Sent: Wednesday, July 19, 2000 6:52 AM
> To: [log in to unmask]
> Subject: [HP3000-L] LinkControl Stats (bit long)
>
> Hi fellow listers,
>
> Given the output of a LINKCONTROL NSLINK;STATUS=ALL command shown
> below,
> could someone tell me if our interface card is running at 10mbs or
> 100mbs.
>
> I can see the link speed value set to 10 so I'm thinking maybe
> 10mbs.
>
> If so, any thoughts on why it's not running at 100mbs.
>
> The card is connected to a 10/100 mbs switch port configured at
> 100mbs and
> the switch port and the card both show indicators to the effect of
a
> 100mbs
> link being established.
>
> ----------------------
>
> Linkname: NSLINK Linktype: 100BT Linkstate: CONNECTED
> Physical Path: 32
> Current Station Address: 00-10-83-96-D0-F4
> Default Station Address: 00-10-83-96-D0-F4
> Current Multicast Addresses:
> 09-00-09-00-00-01
>
> Transmit bytes 4175182330 Receive bytes
> 2419566885
> Transmits 25648006 Receives
> 17110212
> Transmits no error 25644661 Receives broadcast
> 9271268
> Transmits dropped 0 Receives multicast
> 1321
> Transmits deferred 3266 Receives no error
> 27026230
> Transmits 1 retry 2419 CRC or Maxsize error
> 737
> Transmits >1 retry 40 Code or Align error
> 547
> Trans 16 collisions 0 Recv dropped: addr
> 643424
> Trans late collision 3312 Recv dropped: buffer
> 3
> Trans underruns 0 Recv dropped: dma
> 0
> Carrier losses 33 Recv dropped: other
> 2
> Link disconnects 2 Recv deferred
> 0
> Link speed 10 Recv overruns
> 10959
> Link duplex Half Link auto sensed
> Yes
> Link mode 100Base-TX Secs since clear
> 3957309
>
> Thanks for all and any help,
>
> Kevin
>
>
> -=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
> - Kevin O'Sullivan Cosworth Racing Limited,
> -
> - Racing Systems Department The Octagon,
> -
> - St James Mill Road,
> -
> - Northampton, England,
> -
> - NN5 5RA.
> -
> - Tel: +44 (0) 1604 598488
> -
> - mailto:[log in to unmask] Fax: +44 (0) 1604 598506
> -
>
> -=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
> The views expressed above are mine entirely and in no way
represent
> those of my employer.
>
>
>
>
>
****************************************************************************
> ****
> This email and any files transmitted with it are confidential and
> intended solely for the use of the individual or entity to whom
they
> are addressed. If you have received this email in error please
> notify
> the email administrator - [log in to unmask]
>
>
>
****************************************************************************
> ****
>
Billing Concepts Corp., a NASDAQ listed Company, Symbol:BILL
|