You should also set the link duplexing to full instead of half if you hub
supports it.

Carl McNamee
Systems Administrator
Billing Concepts
(210) 949-7282



-----Original Message-----
From: Joseph Dolliver [mailto:[log in to unmask]]
Sent: Wednesday, July 19, 2000 7:26 AM
To: [log in to unmask]
Subject: Re: [HP3000-L] LinkControl Stats (bit long)


I have also seen this problem before. You need to remove autosensing and set
the speed to 100mb "only".

----- Original Message -----
From: Paveza, Gary <[log in to unmask]>
To: <[log in to unmask]>
Sent: Wednesday, July 19, 2000 7:20 AM
Subject: Re: LinkControl Stats (bit long)


> Looks like it is set to 10 MB.  But it also looks like you have
autosensing
> enabled.  If you can nail the card to 100 MB (and the switch/hub/whatever)
> also to 100 you're much better off.  I've always had trouble getting a 100
> MB card get 100 MB if it has autoswitching enabled.
>
> -------------------------------------------------------------
> Gary L. Paveza, Jr.
> Technical Services Manager
> (302) 761-3173 - voice
> (800) 217-5808 - pager
>
>         -----Original Message-----
>         From:   Kevin O'Sullivan [SMTP:[log in to unmask]]
>         Sent:   Wednesday, July 19, 2000 6:52 AM
>         To:     [log in to unmask]
>         Subject:        [HP3000-L] LinkControl Stats (bit long)
>
>         Hi fellow listers,
>
>         Given the output of a LINKCONTROL NSLINK;STATUS=ALL command shown
> below,
>         could someone tell me if our interface card is running at 10mbs or
> 100mbs.
>
>         I can see the link speed value set to 10 so I'm thinking maybe
> 10mbs.
>
>         If so, any thoughts on why it's not running at 100mbs.
>
>         The card is connected to a 10/100 mbs switch port configured at
> 100mbs and
>         the switch port and the card both show indicators to the effect of
a
> 100mbs
>         link being established.
>
>         ----------------------
>
>         Linkname: NSLINK    Linktype: 100BT     Linkstate: CONNECTED
>         Physical Path:              32
>         Current Station Address:    00-10-83-96-D0-F4
>         Default Station Address:    00-10-83-96-D0-F4
>         Current Multicast Addresses:
>          09-00-09-00-00-01
>
>         Transmit bytes             4175182330    Receive bytes
>         2419566885
>         Transmits                    25648006    Receives
>         17110212
>         Transmits no error           25644661    Receives broadcast
>         9271268
>         Transmits dropped                   0    Receives multicast
>         1321
>         Transmits deferred               3266    Receives no error
>         27026230
>         Transmits 1 retry                2419    CRC or Maxsize error
>         737
>         Transmits >1 retry                 40    Code or Align error
>         547
>         Trans 16 collisions                 0    Recv dropped: addr
>         643424
>         Trans late collision             3312    Recv dropped: buffer
>         3
>         Trans underruns                     0    Recv dropped: dma
>         0
>         Carrier losses                     33    Recv dropped: other
>         2
>         Link disconnects                    2    Recv deferred
>         0
>         Link speed                         10    Recv overruns
>         10959
>         Link duplex                      Half    Link auto sensed
>         Yes
>         Link mode                  100Base-TX    Secs since clear
>         3957309
>
>         Thanks for all and any help,
>
>         Kevin
>
>
> -=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
>         - Kevin O'Sullivan                        Cosworth Racing Limited,
> -
>         - Racing Systems Department               The Octagon,
> -
>         -                                         St James Mill Road,
> -
>         -                                         Northampton, England,
> -
>         -                                         NN5 5RA.
> -
>         -                                         Tel: +44 (0) 1604 598488
> -
>         - mailto:[log in to unmask] Fax: +44 (0) 1604 598506
> -
>
> -=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-
>         The views expressed above are mine entirely and in no way
represent
>         those of my employer.
>
>
>
>
>
****************************************************************************
> ****
>         This email and any files transmitted with it are confidential and
>         intended solely for the use of the individual or entity to whom
they
>         are addressed. If you have received this email in error please
> notify
>         the email administrator - [log in to unmask]
>
>
>
****************************************************************************
> ****
>