HP3000-L Archives

January 2002, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
Date:
Sat, 26 Jan 2002 02:02:32 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (49 lines)
We have a client HP9000 accessing the HP3000 as a database server via
IMAGE/SQL on the HP3000 and ALLBASE on the HP9000.  The HP9000 can
successfully connect but is unable to do a select on a table and gets the
following error:

"Invalid TurboIMAGE database access. TurboIMAGE intrinsic 405 [dbget].
(DBERR 13501)"

The user is configured in netutil to log in as CREATOR of the image
database. The same query works if using ISQL on the HP9000, but does not
work
when run from the real application..  Anybody have any ideas of what I may
be missing in
the configuration?

Does anyone know how to duplicate this error message just using ISQL (that
would help get
me started).

From laserrom (I followed the steps suggested but found nothing that is
different from production
which works just fine):
13501      MESSAGE    Invalid TurboIMAGE database access.  TurboIMAGE
                      intrinsic intrinsic number.  (DBERR 13501)

           CAUSE      The TurboIMAGE/XL intrinsic named in the message
                      has returned an error code (-21) indicating a bad
                      password or maintenance word.

           ACTION
                         1.  Make sure the user logon is a valid
                             IMAGE/SQL user for this TurboIMAGE/XL
                             database and the password for the user logon
                             is correct.  (Use the DISPLAY USERS command
                             and DBUTIL's SHOW dbname PASSWORDS command.)
                         2.  Verify the user's access to the data set(s)
                             in the query by checking the read/write list
                             for each data set in the TurboIMAGE/XL
                             schema file.
                         3.  If the password and read/write list security
                             are correct, make sure the user is
                             referencing the correct view.  See Chapter
                             2, Task 3, for information regarding the
                             views that the IMAGE/SQL utility creates and
                             their correct usage.

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2