And terminator.
-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On Behalf
Of Craig Lalley
Sent: Monday, August 13, 2012 12:24 PM
To: [log in to unmask]
Subject: Re: [HP3000-L] N4000-100-330 Issue
Ah, this reminds me of an issue I had once. Seriously.
Check for bent pins on the SCSI cables!
-Craig
--- On Mon, 8/13/12, Dan Barnes <[log in to unmask]> wrote:
From: Dan Barnes <[log in to unmask]>
Subject: Re: N4000-100-330 Issue
To: [log in to unmask]
Date: Monday, August 13, 2012, 10:22 AM
I'll give that a go Craig. Thanks !
Dan
Dan Barnes ..:.. LCI-Lawinger Consulting
106 Central Avenue, Suite A ..:.. Osseo, MN, 55369-1243
Tel: 763-425-1639 ..:.. Fax: 763-425-5483 ..:.. Cell: 612-240-2136 ..:..
Pager: 952-394-0132
[log in to unmask]<mailto:[log in to unmask]> ..:..
[log in to unmask]<mailto:[log in to unmask]>
From: Craig Lalley [mailto:[log in to unmask]]
Sent: Monday, August 13, 2012 12:21 PM
To: [log in to unmask]; Dan Barnes
Subject: Re: N4000-100-330 Issue
Dan,
Considering the last thing that changed was the disk drive, I am going to go
with a hardware issue.
Of course
1349
MESSAGE
ASSIST EXCEPTION TRAP occurred while on the INTERRUPT CONTROL STACK (ICS).
Is it possible to boot into SINGLE-DISC mode? This will tell us if the OS
on Ldev one is corrupt.
START NORECOVERY NOSYSSTART SINGLE-DISC
-Craig
--- On Mon, 8/13/12, Dan Barnes
<[log in to unmask]<mailto:[log in to unmask]>> wrote:
From: Dan Barnes
<[log in to unmask]<mailto:[log in to unmask]>>
Subject: N4000-100-330 Issue
To: [log in to unmask]<mailto:[log in to unmask]>
Date: Monday, August 13, 2012, 10:15 AM
Hi All,
I had rebooted an N-Class (N4000-100-330 on MPE/iX 7.0) server after
replacing an SC10 18gb drive.....I am getting repeated Sys Aborts with the
following when trying to restart the system:
SYSTEM ABORT 1348 FROM SUBSYSTEM 109
SYSTEM HALT 7, $0544
************* SYSTEM ALERT ************** SYSTEM NAME: uninitialized
DATE: 08/13/2012 TIME: 16:46:40
ALERT LEVEL: 12 = Software failure
REASON FOR ALERT
SOURCE: 0 = unknown, no source stated
SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: 0 PROBLEM DETAIL:
0 = no problem detail
LEDs: RUN ATTENTION FAULT REMOTE POWER
FLASH FLASH OFF ON ON LED State: Running
non-OS code. Non-critical error detected.
Check Chassis and Console Logs for error messages.
0xA0E010C00000B007 00000000 00000503 - type 20 = major change in system
state
0x58E018C00000B007 00007007 0D102E28 - type 11 = Timestamp 08/13/2012
16:46:40
A: ack read of this entry - X: Disable all future alert messages Anything
else skip redisplay the log entry
->Choice:
I have 'a' the message, but continue to get the aborts when trying to
restart the system.
Any Ideas ????
TIA, Dan
Dan Barnes ..:.. LCI-Lawinger Consulting
106 Central Avenue, Suite A ..:.. Osseo, MN, 55369-1243
Tel: 763-425-1639 ..:.. Fax: 763-425-5483 ..:.. Cell: 612-240-2136 ..:..
Pager: 952-394-0132
[log in to unmask]<[log in to unmask]> ..:..
[log in to unmask]<[log in to unmask]>
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|