HP3000-L Archives

January 2001, Week 1

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Paul H Christidis <[log in to unmask]>
Reply To:
Paul H Christidis <[log in to unmask]>
Date:
Wed, 3 Jan 2001 14:47:34 -0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (28 lines)
One could also use 'consolan' from within 'sysdiag' to reset the internal
modem using the following:
     DUI >consolan pdev=xxxx section=2(23)
where 'xxxx' is the path id for the console. (in my machine that would be
'10/4/0')

Sysdiag should be run from the system console (ldev 20) and you should
'reset' the remote port.

One can also issue "help consolan sections" from within sysdiag to get more
information on consolan's
functions.

Regards
Paul Christidis




Does anyone know if the internal modems are Hayes command compatible????
If
so, then somehow sending out a Hayes reset command (AT Z????) to the device
LDEV might do this.  In any case it would be usefull to know if internal
modems follow the Hayes command language and how to send commands to them.

Wayne Boyer
Cal-Logic