Vicki Royer wrote:
>
> We are getting ready to upgrade out 957 to 5.5 this week. Has anyone run up
> against any problems that I need to look out for?
> All help appreciated.
If you use any PowerHouse products, version 729C has a problem where you
must press the return key an extra time when you try to run any of the
products, i.e., QUIZ, QTP, QUICK, etc. They have a workaround until
they implement a fix. You might want to call them for details, but
basically you create a file PHRS in the applicable group in the COGNOS
account. The PHRS is a flat file with the work "QUIT" on line 1. It's
just a one record file. Then, put the File equation and Reset-file
equation in the SETPOWERHOUSE and RESETPOWERHOUSE UDCs.
Good Luck!
|
|
|