Brian wrote:
>We got the following error when trying to open our dictionary database:
>(This output is from SIDRIVER, but we get the same error regardless of the
>tool used to open the database.)
>
>Command>!B=1,DICT.PUB
>Command>!M=1
>Command>!Q=;
>Command>O
>ELAPSED TIME (MS) = 83          ; CPU (MS) = 65
>Internal Error in QLOCK operations.
>Command>S
>Integer Status:
>  Word 1 Word 2 Word 3 Word 4 Word 5 Word 6 Word 7 Word 8 Word 9 Word10
>#   -332      0      0      0      0    401  16739 -32338      1      0
 
Hello Brian. The QLOCK table is a new structure that is part of TurboIMAGE,
starting with version C.06.04. It was added as part of the DBQUIESCE
enhancement
for TurboStore True Online Backup. Unfortunately, not all problem scenarios can
be caught during regression testing.
 
Brian, if your current IMAGE version is less than C.06.07, please contact the
HP Response Center and request patch TIXHXG4(C). This is a General Released
(GR)
patch and will bring you up to version C.06.07. If you are currently on
C.06.07,
then the problem may be related to the QLOCK table size being too small. If
this
is the case, then you will need to request the BETA patch, TIXHXP8(A). This
will
bring your version up to C.06.10. However, unless your problem is occuring on a
development machine, I would caution AGAINST putting a BETA patch on a produc-
tion machine. Hope this helps.
 
Best regards,
Steve Patrick
HP Database Expert Center