Dan Eastman asked:
> I have been searching through the FAQ's, and some of the HP Service Center
> material for this and came up 0.
>
> I have a number of HP9000 servers here at the hospital, and a single
> HP3000 running MPE/iX 5.5. I am looking for a way to synchronize the time
> between my 9000's and the 3000. I have the 9000's more or less in step
> but am told there is no way to bring the 3000 in.
>
> Its kind of important since there is always a difference in time with my
> lab and lab tests (which are on the 3000) and the tests as they are
> ordered through one of a couple of the 9000's.
What you want is the POSIX XNTP daemon, which was ported to MPE/iX by Mark
Bixby; here's where you can get it:
http://www.cccd.edu/~markb/xntpix.html
(It's also on the MPE FREEWARE tape, available from Interex; see
http://www.interex.org/sources/freeware.html -- the page is a little out of
date. As is now customary, a new version of the tape will be available
shortly after IPROF.)
---
Michael D. Hensley | mailto:[log in to unmask]
Allegro Consultants Inc. | Visit scenic http://www.allegro.com
408/252-2330 | "Support Bill of Rights Enforcement"