> Sam Knight asked:
>
> How do you set the network port on an HP3000/979 from the AUI port
> to the Thinlan port or does this have to be done by the CE internally?
>
> I want to switch to the Thinlan port so I can connect it to a DTC-48.

And several people replied along these lines:

"It has to be switched by a CE"


I did this myself on a 918.  There was a jumper on the main board that only
has two positions.  Of course, the problem is knowing which jumper to
change.  If you can find someone to tell you which jumper and to what it
should be set, changing it is relatively easy.  But only attempt this if you
are real comfortable messing with hardware.

Jim Phillips                            Manager of Information Systems
E-Mail: [log in to unmask]     Therm-O-Link, Inc.
Phone: (330) 527-2124                   P. O. Box 285
  Fax: (330) 527-2123                   10513 Freedom Street
  Web: http://www.tolwire.com  Garrettsville, Ohio  44231