Hi Admins,

Durin the install of a HP3000 929 with MPE6.5 and PP2 I encountered the
following problem with DSLINE :

:nscontrol status

TOTAL NUMBER OF LOCAL NS USERS:
0
TOTAL NUMBER OF REMOTE NS USERS:
0
TOTAL NUMBER OF NS USERS:
0

SERVICE   TYPE    SERVER    DESCRIPTION

VTA       REMOTE  VTSERVER  INCOMING STREAM MODE VIRTUAL
TERMINAL
NSSTATL   LOCAL   NSSTATUS  OUTGOING NSSTATUS
SERVICE
NSSTAT    REMOTE  NSSTATUS  INCOMING NSSTATUS
SERVICE
LOOPBACK  REMOTE  LOOPBACK  INCOMING LOOPBACK
SERVICE
RPML      LOCAL   DSSERVER  OUTGOING REMOTE PROCESS
MANAGEMENT
RPM       REMOTE  DSSERVER  INCOMING REMOTE PROCESS
MANAGEMENT
VT        REMOTE  VTSERVER  INCOMING VIRTUAL
TERMINAL

SERVICE   STARTED   FEATURES

VTA
YES
NSSTATL
YES
NSSTAT
YES
LOOPBACK
YES
RPML
YES
RPM         YES     AUTOLOGON
ON
VT
YES

SERVER      MIN    MAX  ACTIVE RESERVED DEBUG  PIN  JOBNUM  STATUS

NSSTATUS      0    300       0        0
OFF
LOOPBACK      0    300       0        0
OFF
VTSERVER      0    300       0        0
OFF
DSSERVER      0    300       0        0
OFF

TOTAL NUMBER OF ACTIVE SERVERS:
0
TOTAL NUMBER OF RESERVED SERVERS:
0
TOTAL NUMBER OF SERVERS:
0
:dsline m3rep
ENVIRONMENT 6: M3REP.PHILIPS.NIJMEGEN=M3REP.PHILIPS.NIJMEGEN
:remote
Local vt service has not been started. (CIERR 5036)
Remote command error. (CIERR 5402)
:


I can do a DSLINE and REMOTE from other HP3000 node to the specific node.
Also a NSCONTROL STOP and START didn't help.

Can someone help me with this problem ?

TIA,

Willy Schriemer
System Manager Factory Automation Systems
Philips Semiconductors MOS3 Submicron Waferfab
Building FB 2.018
Gerstweg 2
6534 AE Nijmegen
The Netherlands
Tel. + 31 24 353 2991 or 5716