Hi all,
Thanks for the many responses. The solution was:
turn off "fast file transfer"
set record size to 690
in attributes set record format to stream
set file size to 80000
Thanks again for all you help.
Abraham Zwygart
----- Original Message -----
From: Debus, David <[log in to unmask]>
To: 'Abraham Zwygart' <[log in to unmask]>
Sent: Monday, October 04, 1999 9:15 AM
Subject: RE: WRQ transfer error?
> Abraham,
>
> Find the selection in the transfer configuration for WRQ and turn off
"fast
> file transfer". There is a size limit on
> this kind of transfer via WRQ.
>
> Dave
>
>
> -----Original Message-----
> From: Abraham Zwygart [SMTP:[log in to unmask]]
> Sent: Monday, October 04, 1999 9:46 AM
> To: [log in to unmask]
> Subject: WRQ transfer error?
>
> Hi all,
>
> I am trying to transfer a large file 70,000+ records by 690 char.
> wide from
> my PC to a HP3000 os ver 5.5. Every time I try to transfer WRQ
> gives me
> 'Transfer aborted-record longer then 32767 bytes' Any suggestion on
> how to
> transfer the file?
>
> Thanks for you help
> Abraham Zwygart
> Anodizing Inc.
> Senior Programmer Analysts Email: [log in to unmask]
|
|
|