HP3000-L Archives

February 1999, Week 3

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Doug Hill <[log in to unmask]>
Reply To:
Date:
Fri, 19 Feb 1999 08:56:04 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (18 lines)
Is anyone having problems writing large files to DDS-2 tape drives?
We get this error 2-3 times a week while storing our databases,
"Store encountered media write error on LDEV 8 (S/R 1454)
Specifically, Store recieved error -40 from the I/O system (S/R
1557)."

Our hardware vendor keeps saying it is the drive that has gone bad.
We have swapped out the drives in this spot at least 4-5 times in a
7 month period.  I don't believe it is the drive.

HP says it is a media problem.  We use new tapes and have the
same problem.  Also, we do not get this error on the other two
drives when doing our backups.  I don't believe it's a media problem.

We do have two DDS-2's and 3-4 other disk drives on the same
channel.  Does anyone have any ideas?
Doug.